Standard Water Reduction Polycarboxylic Agent under the brand names MINFRA PC 104. We manufacture and export this product including high speed railways, highways, (air) ports, (hydro) power plants in forms of pre-cast concrete, reinforced concrete pre-stressed concrete.
Technical Data Sheet of Standard Water Reduction Polycarboxylic Agent
Revision No.: 1
Revision Date: 11 / 2018
Product Name | Standard Water Reduction Polycarboxylic Agent |
Trade Name | MINFRA PC 104 |
CAS Number | 97105-14-1 |
MINFRA PC-104 is specialized for gypsum, cement grouting, mortar and other fields. Their addition to concrete or mortar allows the reduction of the water to cement ratio, not affecting the workability of the mixture, and enables the production of self-consolidating concrete and high performance concrete.
Sr. No | Inspection Item | Units | Standard Requirements | Testing Result | Conclusion | ||
---|---|---|---|---|---|---|---|
1 | Cement Paste Fluidity | mm | ≥240 | 253 | Qualified | ||
2 | Density | g/cm3 | 1.11±0.01 | 1.12 | Qualified | ||
3 | Solid Content | % | 50±1.5 | 50.1 | Qualified | ||
4 | PH Value | —— | 6.5~8.5 | 6.6 | Qualified | ||
5 | Water-reducing Rate | % | ≥25 | 30 | Qualified | ||
6 | Air Content | % | ≤3.0 | 2.1 | Qualified | ||
7 | General Bleeding Ratio | % | ≤20 | 0 | Qualified | ||
8 | Pressure Bleeding Ratio | % | ≤90 | 22 | Qualified | ||
9 | Chloridion Content (convert calculating by solid content) | % | ≤0.01 | 0.005 | Qualified | ||
10 | Alkali Content(convert calculating by solid content˅ | % | ≤10 | 1.1 | Qualified | ||
11 | Sodium Sulfate (convert calculating by solid content) | % | ≤5.0 | 0.11 | Qualified | ||
12 | Formaldehyde (convert calculating by solid content) | % | ≤5.0 | 0 | Qualified | ||
13 | Ratio of Compressive Strength | 3d | % | ≥160 | 223 | Qualified | |
7d | % | ≥150 | 210 | Qualified | |||
28d | % | ≥140 | 208 | Qualified | |||
14 | Concretion Time Differences | Initial | min | -90~+120 | +35 | Qualified | |
Final | +40 | Qualified |
The above information is written basing on our current knowledge level, but it is not the guarantee of product characteristics. Since this information may be applied under conditions beyond our control and with which may be unfamiliar and since data made available subsequent to the data hereof may suggest modifications of the information, we do not assume any responsibility for the results of its use.
Note: Information given in this technical data sheet is based on current knowledge and our laboratory evaluation; it is presented as per our opinion without any guarantee. Buyers must carry out their own tests and experiments to determine the suitability and completeness of our products for their use and application.